Search In this Thesis
   Search In this Thesis  
العنوان
Optimization of the Domestic Grey Water Treatment \
المؤلف
Khalil, Mohamed Khaled Hassane.
هيئة الاعداد
باحث / محمد خالد حسان خليل
مشرف / طارق إسماعيل صبرى
مشرف / حسام مصطفي حسين أحمد
مشرف / محمد حسين حجازي
تاريخ النشر
2022.
عدد الصفحات
255 p. :
اللغة
الإنجليزية
الدرجة
ماجستير
التخصص
الهندسة المدنية والإنشائية
تاريخ الإجازة
1/1/2022
مكان الإجازة
جامعة عين شمس - كلية الهندسة - الأشغال العامة
الفهرس
Only 14 pages are availabe for public view

from 255

from 255

Abstract

The reuse of treated grey water is providing a good potential challenge as a secondary source of raw water. Many countries around the world are facing water sacristy and the treatment and potential reuse of the grey water collected from households reduces the dependency on natural diminishing water sources and also reduces the flow of wastewater to sewers and treatment plants; as its treatment can be locally treated on-site.
In Egypt the gap between the available water supplies and the required demands is gradually increasing and it is, currently, estimated that the water demands are more than the available supplies. Wastewater used for domestic purposes represents (80-90) % of the total domestic supplies and if properly treated can be further utilized and reused and add up as a secondary water source. Many technologies are currently adopted for wastewater treatment and they are basically grouped under physical, biological or chemical treatment methods.
Experimental studies on three pilot treatment plants were conducted for a period of about five months. The experimental work was done in the sanitary engineering laboratories of the Faculty of Engineering, British University in Egypt. Grey water was collected from the University buildings and students hostels and the three treatment methods tested included; sand filtration, coagulation and activated sludge.
Results of the operation of the three pilot plants indicated that sand filtration at low flux rates gives treated grey water with acceptable effluent values. Both aluminium sulphate and ferric chloride gave good results at higher coagulant doses. The activated sludge process demonstrated excellent removal efficiencies at higher retention time. In general, the activated sludge process more efficient than the physio-chemical process followed by the physical process.