Search In this Thesis
   Search In this Thesis  
العنوان
Design and Implementation of Electroencephalogram System \
المؤلف
AboSreea,Said Mohsen
هيئة الاعداد
باحث / سعيد محسن أبوسريع حسن
مشرف / أمال زكى محمد
مشرف / محمد عبد الحميد ابو العطا
مناقش / محمد أمين دسوقى
عدد الصفحات
60p.:
اللغة
الإنجليزية
الدرجة
ماجستير
التخصص
الهندسة الكهربائية والالكترونية
تاريخ الإجازة
1/1/2016
مكان الإجازة
جامعة عين شمس - كلية الهندسة - الالكترونيات والاتصالات
الفهرس
Only 14 pages are availabe for public view

from 80

from 80

Abstract

The EEG is important in the medical field. The EEG used to record the brain activities that are used in diagnoses strokes. Recently, the advancement in technology of the brain signals enabled the control of equipment that could help the disabled in their daily life such as wheelchair and robots. Now, mindwave and emotive epock are used in EEG Systems. The EEG recording systems play a major role in the Brain Computer Interface machines where the brainwave signals are given as controls. There is development in transmission of these signals into different platforms based on the portability of applications. This thesis presents a virtual electronic system for measuring the EEG signals. The system consists of electrodes, instrumentation amplifier, filters and a DAQ card with LabVIEW application on a personal computer. The system is developed for displaying, measuring, analyzing and recording the EEG signals. The system is practically implemented with success where the experimental results are verified with simulation results. Hence, the EEG system is developed in order to be portable. The portability is in the first step is based utilizing a data acquisition card DAQ and laptop. Our own system is a low cost system, since the LabVIEW plotter application is developed the EEG system. So, our main target is to design and implement a light weight EEG system with three electrodes. These electrodes are used to sense the signals on human brain which are produced by neurons. The main problems with the brain electrical signals are that they are very small. So, they have to be amplified with special amplifiers. Such amplifiers are called instrumentation amplifiers. These amplifiers are characterized by high gain and common mode rejection ratio in addition to high input impedance. With these specifications, human brain signals can be amplified to get the EEG signal. The filter circuits are also required to clean the contamination and artifacts in EEG signal. The EEG system is developed based on our design with DAQ card and computer. The system is a simple and low cost for acquiring the EEG signals.